Generator box for Honda 3000

A place to discuss non-OEM upgrades and improvements
User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 23rd, 2016, 2:33 am

temperatures recorded on an 85 degree day

https://youtu.be/AeDKHAT2FeA
2015 24 RLS with some mods
2014 Ram 2500 diesel

001
Posts: 51
Joined: March 20th, 2016, 1:12 pm
Location: Central Florida

Re: Generator box for Honda 3000

Post by 001 » April 22nd, 2016, 11:44 am

Very nice

User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 22nd, 2016, 1:17 am

As requested, a video of the genny in operation with temperatures recorded

https://youtu.be/O10y76tGs1w
2015 24 RLS with some mods
2014 Ram 2500 diesel

User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 20th, 2016, 12:18 am

The bolt holding the genny down is 1/2 inches

The hole the bolt goes through the truck bed is 2 3/8 inches

To keep the genny from sliding around and working loose, the wood plugs keeps the bolt, and the genny centered over the 5th wheel hole.
2015 24 RLS with some mods
2014 Ram 2500 diesel

uct
Posts: 255
Joined: April 12th, 2015, 1:20 pm
Location: Blairsville , Ga

Re: Generator box for Honda 3000

Post by uct » April 19th, 2016, 11:58 pm

Houston Remodeler wrote:upper wood plug detail

The bottom 1.5" has the full sized hole for the female nut. The upper section has room for only the carriage bolt. The sections are screwed together to allow everything to be taken apart when the genny goes in for repair.
Please explain the purpose of the wood plugs. Looks good
Gary and Karla Beagles Maddux and Smoltz
2013 f 150 5.0 crew tow package
2016 24 rls

User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 19th, 2016, 7:06 pm

I'll load it into the back of the truck later this week when temps get over 80ºF for a trial run. I'm concerned about the genny overheating, so I'll use my temperature ray gun to check the operating temps as it idles with the eco throttle off.
2015 24 RLS with some mods
2014 Ram 2500 diesel

001
Posts: 51
Joined: March 20th, 2016, 1:12 pm
Location: Central Florida

Re: Generator box for Honda 3000

Post by 001 » April 19th, 2016, 3:14 pm

Houston Remodeler wrote:Yes I can, what would you like to see ?
The operation of it.

User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 19th, 2016, 1:53 pm

Yes I can, what would you like to see ?
2015 24 RLS with some mods
2014 Ram 2500 diesel

001
Posts: 51
Joined: March 20th, 2016, 1:12 pm
Location: Central Florida

Re: Generator box for Honda 3000

Post by 001 » April 19th, 2016, 3:13 am

Can you make video?

User avatar
Houston Remodeler
Posts: 224
Joined: September 23rd, 2015, 6:12 pm
Location: Houston TX
Contact:

Re: Generator box for Honda 3000

Post by Houston Remodeler » April 19th, 2016, 2:42 am

to plug the generator into the TT, an inlet box was purchased (as noted above) along with the cord. The box is mounted to the front of the TT, a wire sent back to the rotary switch.
Attachments
generator inlet open smaller.jpg
generator inlet open smaller.jpg (34.37 KiB) Viewed 3008 times
2015 24 RLS with some mods
2014 Ram 2500 diesel

Post Reply